Siemens SIMODRIVE 611 universal Function Manual page 780

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
0888:16
Function, distributed input (PROFIBUS)
Min
Standard
0
0
... defines which function a signal has which is read-in via the PROFIBUS-PZD for distributed
inputs (DezEing).
The function number from the "list of input signals" is entered. The following applies for the indi-
vidual indices of P0888:
:0 Function DezEing bit 0
:1 Function DezEing bit 1
:2 etc.
0890
Activate angular encoder/encoder interface
Min
Standard
0
0
... defines how the angular encoder interface and encoder interface are operated.
– Angular encoder interface (X461, X462 for "SIMODRIVE 611 universal")
– Encoder interface (X472 for "SIMODRIVE 611 universal E")
0
Angular encoder interface or encoder interface switched-out
1
Angular encoder interface switched-in as output for incremental position actual value
2
Angular encoder interface switched-in as input for incremental position reference value
(from SW 3.3)
3
Angular encoder interface switched-in for drive A as input for the incremental position
reference value. The incremental position actual value from drive A is output at the
angular encoder interface from drive B, if P0890 (B) is 0. P0890 = 3 is only possible for
drive A. (from SW 3.3)
4
Encoder interface enabled as input for TTL encoders (encoder 3, from SW 3.1)
Note:
The terminating resistor must be set for the angular encoder interface ––> switch S1
When entering signals at the angular encoder interface, it should be ensured that the interface
is not parameterized as output. Otherwise, internal and external drivers will operate against
each other and could destroy each other.
refer to the index entry "Angular encoder interface" or "Encoder interface"
0891
Source, external position reference value
Min
Standard
–1
–1
... defines the source for the external position reference value.
–1 not an external position reference value
0
Angular encoder interface
1
Motor encoder, drive A (only drive B in double-axis modules)
(only for compatibility, recommended value = 2)
2
Position actual value drive A (only drive B in double-axis modules, from SW 4.1)
3
Position reference value drive A (only drive B in double-axis modules, from SW 4.1)
4
PROFIBUS DP (from SW 4.1)
Note:
refer under the index entry "axis couplings"
A-780
Max
Unit
83
Max
Unit
4
Max
Unit
4
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Unsigned16
immed.
Data type
Effective
Unsigned16
PO
Data type
Effective
Integer16
PO
E Siemens AG 2005 All Rights Reserved
04.05
01.99
(–> 4.1)
(–> 3.3)