Siemens SIMODRIVE 611 universal Function Manual page 309

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

08.99
Table 5-38
Parameters for PROFIBUS–DP, continued
No.
Description
0952
Number of faults
The parameter specifies the faults which occurred after POWER ON an.
Note:
This parameter is reset at POWER ON.
0953
Warnings 800 – 815
0954
Warnings 816 – 831
0955
Warnings 832 – 847
0956
Warnings 848 – 863
0957
Warnings 864 – 879
0958
Warnings 880 – 895
0959
Warnings 896 – 911
0960
Warnings 912 –927
... indicates which warning(s) is (are) present.
Bit x = 1
warning yyy present
Bit x = 0
a warning is not present
Example:
P0955 = 0110 ––> bits 8 and 4 are set ––> warnings 840 and 836 are present
Parameter
P0953
P0954
P0955
P0956
P0957
P0958
P0959
P0960
0963
Baud rate PROFIBUS
(from
SW 4.1)
... contains the actual baud rate of the PROFIBUS.
0
9.6 kbit/s
1
19.2 kbit/s
2
93.75 kbit/s
3
187.5 kbit/s
4
500 kbit/s
6
1500 kbit/s
7
3000 kbit/s
8
6000 bit/s
9
12000 kbit/s
10
31.25 kbit/s
11
45.45 kbit/s
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
5.9
Parameters
Min.
15 14 13 12 11 10
9
815|814|813|812|811|810|809|808|807|806|805|804|803|802|801|800
831|830|829|828|827|826|825|824|823|822|821|820|819|818|817|816
847|846|845|844|843|842|841|840|839|838|837|836|835|834|833|832
863|862|861|860|859|858|857|856|855|854|853|852|851|850|849|848
879|878|877|876|875|874|873|872|871|870|869|868|867|866|865|864
895|894|893|892|891|890|889|888|887|886|885|884|883|882|881|880
911|910|909|908|907|906|905|904|903|902|901|900|899|898|897|896
927|926|925|924|923|922|921|920|919|918|917|916|915|914|913|912
5 Communications via PROFIBUS DP
Parameter overview of PROFIBUS–DP
Stan-
Max.
dard
hex
hex
hex
hex
hex
hex
hex
hex
8
7
6
5
4
3
2
Units
Effec-
tive
RO
RO
RO
RO
RO
RO
RO
RO
RO
1
0 Bit
RO
5-309
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents