Siemens SIMODRIVE 611 universal Function Manual page 247

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

08.99
05.00
02.02
Example 2:
Assumptions for the example:
Flying
S
measurement
S
Mode
G1_STW.7 = 1
Function 1
G1_STW.0 = 1
Command
G1_STW.4 = 1
(activate function)
G1_STW.5 = 1
(read value)
Function active
G1_ZSW.0 = 1
Value available
G1_ZSW.4 = 1
Measuring probe
deflected
G1_ZSW.8
Measuring probe edge
Actual value transfer
1)
Signal must be reset by user
Fig. 5-15 Function chart for "flying measurement"
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Measuring probe with a positive edge (function 1)
Closed–loop position control with encoder 1
1
Flying measurement
0
1
Measuring probe, positive edge
0
Activate function 1
1
0
1
0
1)
1
0
Function 1 active
1
0
1
0
1
0
5 Communications via PROFIBUS DP
5.6
Net data (PKW and PZD area)
Read value 1
Value 1 available
5
5-247

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents