A.1
Parameter list
0672
Function, input terminal I0.B
Min
Standard
0
0
... defines the function of input terminal I0.B, drive B for the direct measuring system of drive A.
Note:
The function number from the "List of input signals" is entered.
Prerequisite: P0250 = 1 (direct measuring system)
The following functions can be executed via I0.B:
– External block change (function number 67)
– Flying measurement/length measurement (function number 80)
– Equivalent zero mark (function number 79)
0676
Assignment, inputs: Optional TERMINAL module
Min
Standard
0
0
... defines which input terminals on the optional TERMINAL module are assigned to this drive.
0
none
1
Input terminal I4 to I7
2
Input terminals I8 to I11
3
Input terminals I4 to I11
Note:
The terminals can only be assigned to a drive once.
Prerequisite for the assignment: P0875 = 1
Assignment, outputs: Refer to P0696
0678
Image of the input terminals
Min
Standard
The signal statuses of the input terminals are displayed using these parameters.
bit 15 (t. 63/t. 48), bit 14 (t. 663), bit 13 (t. 64), bit 12 (t. 65.x),
bit 11 (t. I11), bit 10 (t. I10), bit 9 (t. I9), bit 8 (t. I8),
bit 7 (t. I7), bit 6 (t. I6), bit 5 (t. I5), bit 4 (t. I4),
bit 3 (t. I3.x), bit 2 (t. I2.x), bit 1 (t. I1.x), bit 0 (t. I0.x)
Bit x = "1" ––> input terminal has signal status "1"
Bit x = "0" ––> input terminal has signal status "0"
Example: P0678 = F004 ––> Term. 63/Term. 48, Term. 663, Term. 64, Term. 65.x and Term.
I2.x have signal status "1"
Note:
Non-assigned bits are displayed with "0".
Terminal I4 to terminal I11 are on the optional TERMINAL module.
0680
Signaling function of output terminal O0.x
Min
Standard
0
33
... defines the function of output terminal O0.x on the control module.
The function is entered from the "List of output signals".
Note:
refer to the index entry "Terminals term. O0.x to O3.x" or "List of the output signals"
A-768
Max
Unit
86
Max
Unit
3
Max
Unit
Hex
Max
Unit
87
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Unsigned16
immed.
Data type
Effective
Unsigned16
immed.
Data type
Effective
Unsigned16
RO
Data type
Effective
Unsigned16
immed.