01.99
04.05
006
Checksum test error. Suppl. info: \%X
Cause
During the continuous check of the checksum in the program/data
memory, a difference was identified between the reference and actual
checksum. The cause is probably a hardware fault on the control mod-
ule.
Supplementary information: only for siemens-internal error diagnostics
Remedy
– Replace control module
Acknowledgement
POWER ON
Stop response
STOP II (SRM, SLM) STOP I (ARM)
007
Error when initializing. Supplementary info: \%X
Cause
An error occurred when loading the firmware from the memory module.
Cause: Data transfer error, FEPROM memory cell defective
Supplementary information: only for siemens-internal error diagnostics
Remedy
Carry-out RESET or POWER-ON.
If a download is still unsuccessful after several attempts, the memory
module must be replaced. If this is unsuccessful the control module is
defective and must be replaced.
Acknowledgement
POWER ON
Stop response
STOP II (SRM, SLM) STOP I (ARM)
020
NMI due to cycle failure
Cause
Basic cycle has failed.
Possible causes: EMC faults, hardware fault, control module
Remedy
– Check the plug-in connections
– Implement noise suppression measures (screening, check ground
– Replace control module
Acknowledgement
POWER ON
Stop response
STOP II (SRM, SLM) STOP I (ARM)
025
SSI interrupt
Cause
An illegal processor interrupt has occurred. An EMC fault or a hardware
fault on the control module could be the reason.
Remedy
– Check the plug-in connections
– Replace control module
Acknowledgement
POWER ON
Stop response
STOP II (SRM, SLM) STOP I (ARM)
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
connections)
7 Fault Handling/Diagnostics
7.3
List of faults and warnings
7
7-631