Siemens SIMODRIVE 611 universal Function Manual page 837

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
04.05
! 611ue diff !
1515:8
Bandwidth, speed setpoint filter 1 (ARM SRM)
Bandwidth, velocity setpoint filter 1 (SLM)
Min
Standard
5.0
500.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1516:8
Numerator, bandwidth speed setpoint filter 1 (ARM SRM)
Numerator, bandwidth velocity setpoint filter 1 (SLM)
Min
Standard
0.0
0.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1517:8
Blocking frequency, speed setpoint filter 2 (ARM SRM)
Blocking frequency, velocity setpoint filter 2 (SLM)
Min
Standard
1.0
3500.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1518:8
Bandwidth, speed setpoint filter 2 (ARM SRM)
Bandwidth, velocity setpoint filter 2 (SLM)
Min
Standard
5.0
500.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1519:8
Numerator, bandwidth speed setpoint filter 2 (ARM SRM)
Numerator, bandwidth velocity setpoint filter 2 (SLM)
Min
Standard
0.0
0.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1520:8
BSP natural frequency, speed setpoint filter 1 (ARM SRM)
BSF natural frequency velocity setpoint filter 1 (SLM)
Min
Standard
1.0
100.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Max
Unit
7999.0
Hz
Max
Unit
7999.0
Hz
Max
Unit
7999.0
Hz
Max
Unit
7999.0
Hz
Max
Unit
7999.0
Hz
Max
Unit
141.0
%
A.1
Parameter list
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.