02.02
Replacing
From delivery date 04.2002 onwards, there will be a new
defective control
"SIMODRIVE 611 universal" or "SIMODRIVE 611 universal E"
boards by new
control board with a higher encoder resolution (refer to Chapter 1.3 or
ones
1.4). This new hardware simultaneously replaces the previous types
and is coupled to the new software qSW 5.1.
"old"
6SN1118–0NV00–0AAV
"SIMODRIVE 611 universal" control board
6SN1118–1NV00–0AAV
6SN1118–0NH10–0AA0 "SIMODRIVE 611 universal E" control board
Fig. 2-3
Replacing a defective control board by a new one
How is a
A control board is installed/removed as follows:
control board
1. Ensure that the power module is in a no–voltage condition.
replaced?
2. Release the screw connection and withdraw the "old" control board
3. Remove the memory module from the defective "old" and insert
4. Insert the "new" control board and connect–up the equipment bus.
5. Install the "SimoCom U" start–up tool with version 5.1 (or higher)
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
2.1
Installing/removing control boards and modules
Replacing control boards
Replacing the option module
(refer to Chapter 2.1 "Installing/removing
an option module")
Replacing the memory module
(refer to Chapter 2.1 "Installing/removing
a memory module")
from the power module.
this into the "new" control board, refer to Point "Installing/removing a
memory module".
or, when using an "older" version, observe the following information: