Siemens SIMODRIVE 611 universal Function Manual page 535

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
! not 611ue !
M
mode via
Prerequisites:
set
term. 56.x/14.x
S
and
S
M
mode via
red
term. 24.x/20.x
Offset
P0610
correction
T. 56.x
A
" 10 V
D
T. 14.x
+
T. 24.x
+
A
" 10 V
D
T. 20.x
Offset
P0615
correction
Fig. 6-56 Open–loop torque controlled operation via terminal 56.x/14.x and torque/power reduction via
terminal 24.x/20.x
Reader's note
The torque/power reduction via terminal 24.x/20.x is described in
Chapter 6.6.4.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
"Open–loop torque controlled operation" input signal = 1 signal
P0607 = 1
Torque setpoint via terminal 56.x/14.x
P0612= 2
Setpoint for M
P0608
P0609
Smoothing
Inver-
time
sion
PT
filter
1
P0613
P0614
Smoothing
Inver-
time
sion
PT
filter
1
6 Description of the Functions
6.6
via terminal 24.x/20.x
red
Offset
P1242:8
torque
setpoint
P0619
P1241:8
+
Scaling
torque
M
setpoint
set
analog
(refer to Chapter
6.1.2)
Scaling
torque/
power
reduction
Character–
P0620
istic
P1243:8
P1244
Analog inputs
P1230
P1235
X
M
red
analog
(refer to
Chapter 6.1.2)
6-535