! not 611ue !
Angular
incremental
encoder signals
for resolvers
1 pulse
A+.x
B+.x
R+.x
A+.x/B+.x/R+.x: Angular incremental encoder signals (x: space retainer for drive A or B)
P: Pole pair number of the resolver
Fig. 6-66 Angular incremental encoder signals for resolvers
Angular
incremental
encoder signals
for incremental
encoders with
sin/cos 1Vpp
Signal A
90_
Signal B
A+.x
B+.x
R+.x
Fig. 6-67 Angular incremental encoder signals for incremental encoders with sin/cos 1Vpp
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6.8
Angular incremental encoder interface (X461, X462)
1 pulse (8 360_)
1 zero pulse/rev
6 Description of the Functions
P = 1 ––> 1024 pulses/rev
P = 2 ––> 2048 pulses/rev
P = 3 ––> 3072 pulses/rev
P = 4 ––> 4096 pulses/rev
No. of pulses = P S 1024
P = 1 ––> 1 zero pulse/rev
P = 2 ––> 2 zero pulses/rev
P = 3 ––> 3 zero pulses/rev
P = 4 ––> 4 zero pulses/rev
Distance between the zero pulses =
1024 pulses
Encoder signals
Angular incremental
encoder signals
x: Space retainer for
drive A or B
6