Siemens SIMODRIVE 611 universal Function Manual page 483

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
08.01
! 611ue diff !
Table 6-45
List of input signals, continued
Signal name, description
Selection, parking axis
The drive can be declared a "parking axis", using this input signal.
1 signal
"Parking axis" selected
The parking axis selection is only activated when the pulses are canceled or the controller
is inhibited with subsequent pulse cancellation (e.g. using terminal 663, 63, 65.x, control
signal ON/OFF 1) (refer to the output signal "parking axis selected").
The encoder–specific monitoring functions are suppressed for a parking axis.
The output signal "reference point set" is withdrawn.
0 signal
"Parking axis" canceled
The monitoring functions are active corresponding to the setting in P1600.
Application:
It is possible to change over from one motor encoder unit to another unit using the "parking axis" function,
without having to power down the drive.
Note:
After the "parking axis" function has been canceled, the following is valid:
S
Incremental measuring system:
S
Absolute measuring system (EnDat):
The adjustment status cannot be withdrawn by just selecting or canceling the "parking axis" function.
This status is only permanently withdrawn when an another absolute value encoder has also been auto-
matically detected.
Opening the holding brake for test purposes (from
SW 4.1)
A holding brake can be opened for test purposes during the commissioning phase using this input signal.
1 signal
The function is activated
0 signal
De–activates the function
Note:
This input signal is only evaluated if the brake control is activated using P0850 = 1. In the operating
mode, the brake is controlled using P0850 (operating sequence control) and not via this input signal.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6.4
Input/output terminals of the control board
Fct. No.
n–set
40
The axis must be re–referenced (refer to Chapter 6.2.5).
The axis must be re–adjusted (refer to Chapter 6.2.7).
42
6 Description of the Functions
Operating
mode
pos
PROFIBUS bit
x
x
STW2.7
x
x
STW1.12
6-483
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents