Siemens SIMODRIVE 611 universal Function Manual page 783

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
04.05
! 611ue diff !
0898
Modulo range master drive
Min
Standard
0
0
... informs the slave drive about the selected modulo range for the master drive.
Note:
The following applies: P0242 (master drive) = P0898 (slave drive)
The value 0 switches-out the modulo correction.
refer under the index entry "axis couplings"
0899:8
Enter angular incremental encoder direction
Min
Standard
0
0
... defines in which direction the angular incremental encoder interface pulses are permitted.
0
positive and negative direction
1
only the positive direction
2
only the negative direction
Note:
refer to the index entry "Angular encoder interface"
0900:4
Angular incremental encoder, handwheel evaluation
Min
Standard
1
1
... defines the factor with which the handwheel pulses are evaluated.
Note:
refer to the index entry "Angular encoder interface"
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Max
Unit
100000000
MSR
Max
Unit
2
Max
Unit
10000
A.1
Parameter list
(–> 3.5)
Data type
Effective
Unsigned32
PO
(–> 8.1)
Data type
Effective
Unsigned16
immed.
(–> 8.1)
Data type
Effective
Unsigned16
immed.