Parameter list
0607
Analog setpoint term. 56.x/14.x
Min
Standard
0
1
... defines whether and how the analog setpoint is used at this analog input.
0
off
1
n-set/M-set operation (speed or torque setpoint interface, refer to Note)
2
Override (position setpoint interface and positioning)
Note:
It is always possible to toggle between n-set/M-set operation using the "Open-loop torque-con-
trolled operation" input signal.
Analog setpoint for n-set/M-set ––> refer to the index entry "Analog inputs"
Analog setpoint for velocity override ––> refer to the index entry "Override"
0608
Inversion term. 56.x/14.x
Min
Standard
0
0
An inversion inverts the polarity of the analog setpoint at this terminal internally.
1
Inverted
0
Not inverted
0609
Smoothing time, terminal 56.x/14.x
Min
Standard
0.0
3.0
0.0
0.0
This allows the output value of the A/D converter to be smoothed using a PT1 filter.
0610
Drift/offset correction term. 56.x/14.x
Min
Standard
–9999.9
0.0
If the motor erroneously rotates when a speed setpoint of 0 V is entered, a voltage offset can
be applied to set the analog input to zero using this parameter.
0611
Voltage at term. 24.x/20.x
Min
Standard
... displays the analog voltage presently available at this input terminal.
0612
Analog setpoint term. 24.x/20.x
Min
Standard
0
0
... defines whether and how the analog setpoint is used at this analog input.
0
off
1
n-set/M-set operation (refer to Note)
2
M-red operation
3
Equalization controller operation
Note:
It is always possible to toggle between n-set/M-set operation using the "Open-loop torque con-
trolled mode" input signal.
Analog setpoint for n-set/M-set/M-red ––> refer to the index entry "Analog inputs"
Analog setpoint for velocity override ––> refer to the index entry "Override"
A-756
Max
Unit
2
Max
Unit
1
Max
Unit
1000.0
ms
1000.0
ms
Max
Unit
9999.9
mV(pk)
Max
Unit
V(pk)
Max
Unit
3
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Unsigned16
immed.
Data type
Effective
Unsigned16
immed.
Data type
Effective
Floating Point
immed. (ARM)
Floating Point
immed. (SRM SLM)
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
RO
Data type
Effective
Unsigned16
immed.