Siemens SIMODRIVE 611 universal Function Manual page 306

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

5 Communications via PROFIBUS DP
5.9
Parameter overview of PROFIBUS–DP
Table 5-38
Parameters for PROFIBUS–DP, continued
No.
0879
PROFIBUS configuration (from SW 3.1)
Bit 2, 1, 0 Permissible sign–of–life error
Bit 8
Operation with/without master sign–of–life monitoring
Bit 11
PKW area: Sub–index in the high/low byte of IND (from SW 3.3)
Bit 12
Activates the direct measuring system (encoder 2) for the encoder interface (from
SW 3.3)
Bit 13
Incremental motor measuring system with/without equivalent zero mark
Bit 14
Incremental, direct meas. system with/without equivalent zero mark (from SW 3.3)
0880
Speed evaluation PROFIBUS (SRM,
ARM)
Motor velocity evaluation PROFIBUS
(SLM)
... defines the normalization of the speed or velocity when using PROFIBUS–DP.
4000
or 16384
Hex
0881
Evaluation, torque/power reduction
(from
PROFIBUS (SRM, ARM)
SW 4.1)
Evaluation, force/power reduction
PROFIBUS (SLM)
... defines the normalization of the torque/power reduction or force/power reduction when us-
ing PROFIBUS–DP.
Note:
4000 hex or 16384 dec in the control word MomRed corresponds to a reduction by the per-
centage specified in P0881.
0882
Torque setpoint evaluation
(from
PROFIBUS (SRM, ARM)
SW 4.1)
Force setpoint evaluation
PROFIBUS (SLM)
... defines the normalization of the torque or force setpoint when entered via PROFIBUS–DP.
Note:
P0882 is a percentage value referred to the rated motor torque. The parameter acts on the
process data MsollExt (torque setpoint external in the input direction) and Msoll (torque set-
point in the output direction).
4000 hex or 16384 dec in the control word corresponds to the percentage entered into P0882.
0883
Override evaluation, PROFIBUS
(from SW 3.1)
... defines the normalization of the override when entered via PROFIBUS DP.
4000
or 16384
hex
0884
PROFIBUS position output evaluation
(from
number of increments
SW 4.1)
... defines the normalization of the override when entered via PROFIBUS.
4000
or 16384
hex
5-306
Parameters
Description
 of the speed or velocity in P0880
Dec
 the override in P0883
dec
 the override in P0883
dec
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Min.
Stan-
Max.
dard
0
1
FFFF
0.0
16 384.0
100 000.0
0.0
16 384.0
16 384.0
800.0
16 384.0
–16384.0
0.0
16 384.0
16 384.0
1
2048
8388607
E Siemens AG 2005 All Rights Reserved
08.99
05.00
08.01
08.01
Units
Effec-
tive
hex
PO
RPM
Imme-
diately
m/min
%
Imme-
diately
%
%
Imme-
diately
%
%
Imme-
diately
PO