Siemens SIMODRIVE 611 universal Function Manual page 108

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

3 Parameterizing the Board
3.3
Parameterizing using the parameterizing and start–up tool SimoCom U
Serial interface
(e.g. COM 1)
PG/PC
3rd board
Drive A: P0801 = 1
Drive B: P0801 = 1
Drive A: P0802 = 5
Drive B: P0802 = 3
Terminating resistor in
S1: Switch 7 = ON
S1: Switch 8 = ON
1
9
Fig. 3-10 Communications via RS485 (example with 3 nodes)
3-108
Basic solution for the example:
RS232/RS485
interface converter
PC/PPI
RS232
cable
Ç Ç
Ç Ç Ç Ç
9–pin
socket
2nd board
Drive A: P0801 = 1
Drive B: P0801 = 1
Drive A: P0802 = 7
Drive B: P0802 = 8
Terminating resistor out
S1: Switch 7 = OFF
S1: Switch 8 = OFF
1
9
Note
Essentially the same as when specifying the possible node addresses
(drive numbers), up to 31 drives can be connected to an
RS232/RS485 interface converter (PC/PPI cable).
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
RS485
Terminating resistor 120 Ω
1st board
Drive A: P0801 = 1
Drive B: P0801 = 1
Drive A: P0802 = 4
Drive B: P0802 = 2
Terminating resistor out
S1: Switch 7 = OFF
S1: Switch 8 = OFF
9–pin
socket
9–pin
1
plug
9
E Siemens AG 2005 All Rights Reserved
01.99
05.00
07.03
! 611ue diff !
Ç Ç Ç
9–pin
plug
9–pin
socket
Ç Ç
Ç
Ç Ç
Ç
2
3
7
8
0 V
+24 V
Data +
Data –

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents