0026
Position actual value, external block change
Min
Standard
... displays, in the "Positioning" mode, the position actual value displayed when an edge is de-
tected at the "External block change" input signal.
Note:
The parameter is reset when starting a traversing block with the block change enable CON-
TINUE EXTERNAL.
refer to the index entry "block step enable – CONTINUE EXTERNAL"
0029
Following error
Min
Standard
... in the "positioning" mode and for the "Spindle positioning" function, displays the actual follow-
ing error.
The following error is the difference between the position setpoint (before the position setpoint
filter, interpolator output) and the position actual value.
Note: refer to the index entry "Kv factor" or "Analog signals for the position control loop"
0030
Control deviation, position controller input
Min
Standard
... in the "positioning" mode and for the "Spindle positioning" function, displays the actual
system deviation (reference value – actual difference) at the position controller input.
Note: refer to the index entry "Kv factor" or "Analog signals for the position control loop"
0031
Actual Kv factor (position loop gain)
Min
Standard
... in the "positioning" mode and for the "Spindle positioning" function, displays the actually avail-
able (measured) Kv factor.
Example:
A kv factor = 1 has been set in P0200:8.
When traversing the axis, the current (measured) Kv factor is calculated and displayed in this
parameter.
Note:
The actual Kv factor display (P0031) can have large values at low velocities due to the round-
ing-off errors.
At standstill, the selected (required) Kv factor (P0200:8) is displayed.
0032
Position reference value, external
Min
Standard
... displays the externally entered position reference value.
Note:
The quantities of P0895 to P0897 are incorporated in P0032.
refer under the index entry "axis couplings"
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Max
Unit
MSR
Max
Unit
MSR
Max
Unit
MSR
Max
Unit
1000/min
Max
Unit
MSR
A.1
Parameter list
(–> 3.1)
Data type
Effective
Integer32
RO
Data type
Effective
Integer32
RO
Data type
Effective
Integer32
RO
Data type
Effective
Floating Point
RO
(–> 3.3)
Data type
Effective
Integer32
RO
A Lists
A
A-735

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents