Connecting induction motors with TTL encoder (from SW 8.1)

Description
Standard square–wave encoders (TTL) with differential signals accor-
ding to RS422 and 5 V power supply voltage can be connected as
pulse encoder for induction motors to the control board "SIMODRIVE
611 universal HR" (Order No. 6SN1118–VNH01–0AAV).
The maximum encoder limiting frequency is 420 kHz.
Connection
Encoder connection
Pin assignment of the interface:refer to Chapter 2.4
Encoder cable:
Max. cable length:
Note
If an induction motor with TTL encoder is connected to "SIMODRIVE
611 universal HR", then it is not permissible that the angular
incremental encoder interface is used as output.
Warning
!
If individual or several signals of the encoder are short–circuited or
interrupted – under certain circumstances – it is possible that the
encoder signal monitoring does not respond and the motor can move
in an uncontrolled fashion.
Parameter
The following parameters are available for connecting an induction
overview
motor with TTL encoder:
(refer to Chapter
S
A.1)
S
S
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
4.12 Connecting induction motors with TTL encoder (from SW 8.1)
P1011
IM configuration, actual value sensing
P1005
IM encoder pulse number
P1027
IM configuration, encoder
4 Commissioning
X411/X412
Users must assemble these themselves
50 m
4
J
4-197