Siemens SIMODRIVE 611 universal Function Manual page 807

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
04.05
! 611ue diff !
1043
Encoder 1 fine resolution, absolute track G1_XIST2
Min
Standard
0
9
... defines how many fine resolution bits are transferred for the PROFIBUS encoder interface.
This parameter applies for the fine resolution of process data G1_XIST2 when reading the ab-
solute value.
Note:
The parameter is only valid for the absolute track of the absolute value encoder.
The fine resolution for the value display for reference mark or flying measurement is defined in
P1042.
1044
Encoder 2 fine resolution G2_XIST1
Min
Standard
0
11
... defines how many fine resolution bits are transferred for the PROFIBUS encoder interface.
This parameter applies for the following:
– Fine resolution for process data G2_XIST1
– Fine resolution for G2_XIST2 for reference mark or flying measurement
1045
Encoder 2 fine resolution, absolute track G2_XIST2
Min
Standard
0
9
... defines how many fine resolution bits are transferred for the PROFIBUS encoder interface.
This parameter applies for the fine resolution of process data G2_XIST2 when reading the ab-
solute value.
Note:
The parameter is only valid for the absolute track of the absolute value encoder.
The fine resolution for the value display for reference mark or flying measurement is defined in
P1044.
1050
IM reference mark clearance for distance-coded scales (–> 4.1)
Min
Standard
0
20000
...specifies the basic clearance between two fixed reference marks. If the closed-loop identifies
that the distance between each second reference mark is different and is therefore incorrect,
the axis remains stationary. Fault 508 (zero mark monitoring, motor measuring system) is sig-
naled.
Note:
IM ––> Indirect measuring system (motor encoder)
This monitoring is only activated if P1050/P1024*1000 can either be divided by 16 or by 10.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Max
Unit
11
Max
Unit
11
Max
Unit
11
Max
Unit
µm
4294967295
A.1
Parameter list
(–> 3.3)
Data type
Effective
Unsigned16
PO
(–> 3.3)
Data type
Effective
Unsigned16
PO
(–> 3.3)
Data type
Effective
Unsigned16
PO
Data type
Effective
Unsigned32
PO
A Lists
A
A-807

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents