6 Description of the Functions
6.4
Input/output terminals of the control board
Table 6-45
List of input signals, continued
Signal name, description
Motor changed over (from SW 2.4)
For P1249 = 1 motor changeover is controlled via this input signal.
1 signal
Initial status
1/0 signal
Pulse enable is withdrawn
0 signal
Initial status, selecting a motor corresponding to the motor data set
0/1 signal
Enable the pulses
Input signals (selection)
Motor data set changeover 1st input,
motor data set changeover 2nd input
Control signal STW2.11
"motor changed over"
Pulse enable
(SIMODRIVE 611 universal
internal)
Output signals
Actual motor 1st signal (ZSW2.9)
Actual motor 2nd signal (ZSW2.10)
Output signal
"status, controller enable"
(ZSW1.2)
Output signals from the SIMATIC
S7
(Contactor control)
Selects the required motor data set
1
Signal to "SIMODRIVE 611 universal": The pulse enable is internally withdrawn after STW2.11 = 0
2
The motors are only changed over when the pulses have been canceled (switched–in a no–current
3
condition)
4
Selects the motor corresponding to the motor data set
5
Signal to "SIMODRIVE 611 universal": enable the pulses (STW2.11 edge 0 – 1)
Note:
The "motor changeover" function is described in Chapter 6.11.
6-496
Fct. No.
Motor data set x
1
0
1
0
Motor data set x
off
1
0
1
0
1
0
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Operating
mode
n–set
pos
PROFIBUS bit
x
STW2.11
Motor data set y
1
2
5
3
Motor data set y
on
Motor x off
4
Motor y on
E Siemens AG 2005 All Rights Reserved
08.01
01.99