Siemens SIMODRIVE 611 universal Function Manual page 782

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
0893
Angular encoder zero pulse offset
Min
Standard
–360.0
0.0
... shifts the zero pulse of an encoder.
The zero pulses for the angular encoder interface are generated in the encoder hardware. For
encoders with sin/cos 1 Vpp, there is 1 zero pulse per mechanical revolution. For resolvers,
there is 1 zero pulse for each electrical revolution, i.e. for a resolver with pole pair number = 3,
there are 3 zero pulses per mechanical revolution.
Note:
In order that the zero pulse offset is correctly taken into account, the drive must remain station-
ary while the control module is running up.
refer to the index entry "Angular encoder interface"
0894
Angular encoder input signal waveform
Min
Standard
0
0
... defines the input signal shape for the angular encoder interface.
0 Quadrature signal
1 Pulse/direction signal
2 Forwards/reverse signal
Note:
refer to the index entry "Angular encoder interface"
0895
External position reference value – no. of increments
Min
Standard
1
10000
... together with P0896, defines, for couplings, the ratio between the input increments and di-
mension system grids.
Note:
––> P0895 input pulses at the angular encoder correspond to P0896 MSR
––> Setpoint input from P0895 corresponds to P0896 MSR
refer to P0896
refer under the index entry "axis couplings"
0896
Ext. position ref. value – no. of dimension system grids (–> 3.3)
Min
Standard
1
10000
... together with P0895, defines for couplings, the ratio between the input pulse periods (or input
bit) and the measuring system grid.
Note:
refer to P0895
refer under the index entry "axis couplings"
0897
Invert external position reference value
Min
Standard
0
0
... defines whether the position reference value is entered externally and therefore the direction
should be inverted.
1
position setpoint inversion
0
Not inverted
Note:
refer under the index entry "axis couplings"
A-782
Max
Unit
360.0
Degree
Max
Unit
2
Max
Unit
8388607
Max
Unit
8388607
MSR
Max
Unit
1
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Floating Point
PO
Data type
Effective
Unsigned16
PO
Data type
Effective
Unsigned32
PO
Data type
Effective
Unsigned32
PO
Data type
Effective
Unsigned16
PO
E Siemens AG 2005 All Rights Reserved
04.05
01.99
(–> 3.3)
(–> 3.3)
(–> 3.3)