Mini connector
For the "SIMODRIVE 611 universal" control board, a compact connec-
MICRO–
tor is used (this is also known as mini connector).
COMBICON
The following information is required when handling this mini connector:
S
S
Test sockets
To measure the voltage at a terminal,
a measuring probe with max. ∅ 1 mm
diameter can be inserted in this
socket.
Designation
The self–adhesive
labeling strips can
then be attached.
Lever–type opener
The terminal contact to introduce the conductor or to release a
conductor is opened using this element.
pressed
––>
not pressed
––>
Fig. 2-4
Compact connector (Mini connector)
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Introducing conductors (refer to Fig.2-4):
– for solid conductors with 0.2 – 0.5 mm
with end sleeve
The conductors can be introduced without having to use a tool.
Procedure:
Insert the conductor into the required terminal.
– for solid conductors < 0.2 mm
end sleeve
The lever–type opener must be pressed in order to introduce the
conductor (e.g. using a screwdriver 0.4 S 2.0 S 20 mm).
Procedure:
Depress the lever–type opener below to the particular terminal.
Insert the conductor into the opening provided and then release
the lever–type opener.
Coding (refer to Fig. 2-4):
The connectors with the same number of pins should be coded so
that the incorrect connector cannot be inserted. A star with 6 individ-
ual coding profile is supplied with each control board.
Procedure:
Insert the coding element into the required coding groove on the
base housing. Now break–off the appropriate coding lug at the con-
nector section (e.g. coding groove/lug 2).
Connector part
Base housing
terminal contact opened
terminal contact closed
2 Installing and Connecting-Up
2.2
Connecting–up
2
or stranded conductors
2
or stranded conductors without
Coding grooves
The coding elements are
inserted here
(red insulating material)
Coding lugs
The appropriate lugs
are broken off for
coding.
Introducing the conductor
2
(max. 0.5 mm
)
S
Finely–stranded
conductor
or
S
solid conductor
8 mm
2
2-67