A Lists
A.1
Parameter list
0008
Actual traversing block – mode
Min
Standard
–
–
... in the "Positioning" mode and for the "Spindle positioning" function it specifies the pro-
grammed mode of the traversing block being processed.
Note: refer to the index entry "Traversing blocks" or P0087:64
0020
Position setpoint
Min
Standard
–
–
... in the "positioning" mode and for the "Spindle positioning" function, displays the actual abso-
lute reference position.
0021
Position actual value
Min
Standard
–
–
... in the "positioning" mode and for the "Spindle positioning" function, displays the actual
system deviation (reference value – actual difference) at the absolute actual position.
0022
Distance to go
Min
Standard
–
–
... in the "positioning" mode and for the "Spindle positioning" function, displays the distance to
go.
The distance to go is the difference up to the end of the actual traversing block (P0001).
0023
Velocity setpoint
Min
Standard
–
–
... in the "positioning" mode and for the "Spindle positioning" function, displays the actual
system deviation (reference value – actual difference) at the actual setpoint – traversing veloc-
ity.
0024
Actual velocity
Min
Standard
–
–
... in the "positioning" mode and for the "Spindle positioning" function, displays the actual tra-
versing velocity.
0025
Effective override
Min
Standard
–
–
... in the "Positioning" mode displays the actual, effective velocity override.
Note:
The currently effective override can differ from the specified override due to limits (e. g. P0102
(maximum velocity)).
A-734
Max
Unit
–
Hex
Max
Unit
–
MSR
Max
Unit
–
MSR
Max
Unit
–
MSR
Max
Unit
–
c*MSR/min
Max
Unit
–
c*MSR/min
Max
Unit
–
%
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Unsigned16
RO
Data type
Effective
Integer32
RO
Data type
Effective
Integer32
RO
Data type
Effective
Integer32
RO
Data type
Effective
Integer32
RO
Data type
Effective
Integer32
RO
Data type
Effective
Floating Point
RO
E Siemens AG 2005 All Rights Reserved
04.05
01.99