Siemens SIMODRIVE 611 universal Function Manual page 848

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
1735
Processor utilization
Min
Standard
... continuously displays (online) the processor utilization and provides information about the
available computation time reserves of the processor.
The processor utilization is essentially dependent on the number of axes, operating mode and
cycle setting.
P1735 > 90 %
If, after start-up (optimization), this is displayed as "normal status", then there is a high danger
that if additional computation time-intensive functions are selected, the processor will be over-
loaded (e.g. measuring function).
Note:
If processor utilization is too high it can be reduced by increasing the clock cycles (refer to the
index entry "cycles").
P1735 < 90 %
From experience, there are no problems here, so that later (e.g. when troubleshooting), supple-
mentary functions (e.g. measuring functions, trace functions) can be temporarily activated.
1736
Test, rotor position identification (SRM SLM)
Min
Standard
0
0
To check the rotor position identification, using this test function, the difference between the cal-
culated rotor position angle, and that currently used by the control, can be determined.
1
The rotor position identification test has been activated
––> the difference is entered in P1737
0
The test has been completed (initial status)
Note:
refer under the index entry "Rotor position identification", "PE spindle" or "Linear motor"
1737
Difference, rotor position identification (SRM SLM)
Min
Standard
Note:
also referfor P1736 and under the index entry "PE spindle" or "linear motor"
The rotor position identification is described in:
References: /FBA/, Description of Functions, Drive Functions, Section DM1
1738
No. of data backup operations in the FEPROM
Min
Standard
Note: Internal Siemens
1739
You must save in the FEPROM
Min
Standard
... displays that at least one parameter was written into and the value was not yet saved in the
non-volatile memory (FEPROM).
1
Must be saved in the FEPROM because parameters have been changed
0
Need not be saved in the FEPROM
A-848
Max
Unit
%
Max
Unit
1
Max
Unit
Degree
Max
Unit
Max
Unit
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Unsigned16
RO
Data type
Effective
Unsigned16
immed. (SRM SLM)
Data type
Effective
Floating Point
RO
Data type
Effective
Unsigned32
RO
Data type
Effective
Unsigned16
RO
E Siemens AG 2005 All Rights Reserved
01.99
04.05
(SRM SLM)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents