2 Parameters
2.2 List of parameters
r7835[0...23]
Telegram diagnostics real / Telegr diag real
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Parameter to display a DSA signal in the float format.
The associated signal number is represented at the appropriate index in r7831.
r7836[0...23]
Telegram diagnostics unit / Telegr diag unit
Access level: 4
Can be changed: -
Unit group: -
Min
-1
Description:
Displays the units of a DSA signal.
The associated signal number is represented at the appropriate index in r7831.
Value:
-1:
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
16:
18:
19:
20:
21:
22:
23:
24:
25:
26:
28:
29:
30:
31:
32:
33:
34:
35:
36:
38:
39:
40:
42:
43:
44:
45:
498
Unknown
None
Millimeter or degrees
Millimeter
Degrees
mm/min or RPM
Millimeter / min
Revolutions / min
m/sec^2 or U/sec^2
m/sec^2
U/sec^2
m/sec^3 or U/sec^3
m/sec^3
U/sec^3
sec
16.667 / sec
mm/revolution
ACX_UNIT_COMPENSATION_CORR
Newton
Kilogram
Kilogram meter^2
Percent
Hertz
Volt peak-to-peak
Amps peak-to-peak
Degrees Celsius
Degrees
Millimeter or degrees
Meters / minute
Meters / second
ohm
Millihenry
Newton meter
Newton meter/Ampere
Volt/Ampere
Newton meter second / rad
31.25 microseconds
Microseconds
Milliseconds
Kilowatt
Micro amps peak-to-peak
Volt seconds
Microvolt seconds
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
147
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
-
SINAMICS G120 CU250S-2 Control Units