2 Parameters
2.2 List of parameters
Note:
The delay time must be set to a value greater than the debounce time (p10017).
Regardless of p10001, the forced checking procedure will pause for at least two safety monitoring clock cycles
between each stage of the test.
The test stop is only performed if the safety output is being used (see p10042).
p10002
SI Motion F-DI changeover discrepancy time (processor 1) / SI Mtn DI chg t P1
Access level: 3
Can be changed: C(95)
Unit group: -
Min
1.00 [ms]
Description:
Sets the discrepancy time for digital inputs.
The signal states at the two associated digital inputs (F-DI) must assume the same state within this discrepancy time.
Dependency:
Refer to: p10102
p10003
SI Motion forced checking procedure timer / SI Mtn dyn t
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0.00 [h]
Description:
Sets the time to carry out the forced checking procedure (test stop).
Within the parameterized time, the digital inputs/outputs must must have been subject to a forced checking
procedure at least once. The forced checking procedure is started with binector input p10007 = 0/1 signal.
Dependency:
Refer to: p10002, p10007, p10046
p10006
SI Motion acknowledgment internal event F-DI (processor 1) / SI Mtn ackn int P1
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0
Description:
Select a fail-safe digital input (F-DI) for the signal "acknowledge internal event" (internal fault).
The falling edge at this input resets the status "internal event" in the drive.
The rising edge at this input acknowledges any existing discrepancy errors.
Value:
0:
1:
2:
3:
255:
Dependency:
Refer to: p10106
Refer to: A01666, A30666
Note:
The values "static selected" and "static deselected" result in an inactive function of the safe acknowledgment.
F-DI: Fail-safe Digital Input
p10007
BI: SI Motion forced checking procedure F-DO signal source / SI dynF-DI/DOs_src
Access level: 3
Can be changed: C(95)
Unit group: -
Min
-
Description:
Selects an input terminal to start the test stop.
The test stop is started with a 0/1 signal at the input terminal and is then only possible if the drive is not in
commissioning mode.
598
Static selected
F-DI 0
F-DI 1
F-DI 2
Static deselected
Calculated: -
Scaling: -
Unit selection: -
Max
2000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
8760.00 [h]
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
500.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
8.00 [h]
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 2848
Factory setting
0