Siemens SINAMICS G120 List Manual page 459

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

p3835[0...n]
Friction characteristic value M5 / Friction M5
Access level: 2
Can be changed: T
Unit group: 7_1
Min
-1000000.0000 [Nm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 6th value pair of the friction characteristic.
Dependency:
Refer to: p3825, p3845
p3836[0...n]
Friction characteristic value M6 / Friction M6
Access level: 2
Can be changed: T
Unit group: 7_1
Min
-1000000.0000 [Nm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 7th value pair of the friction characteristic.
Dependency:
Refer to: p3826, p3845
p3837[0...n]
Friction characteristic value M7 / Friction M7
Access level: 2
Can be changed: T
Unit group: 7_1
Min
-1000000.0000 [Nm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 8th value pair of the friction characteristic.
Dependency:
Refer to: p3827, p3845
p3838[0...n]
Friction characteristic value M8 / Friction M8
Access level: 2
Can be changed: T
Unit group: 7_1
Min
-1000000.0000 [Nm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 9th value pair of the friction characteristic.
Dependency:
Refer to: p3828, p3845
p3839[0...n]
Friction characteristic value M9 / Friction M9
Access level: 2
Can be changed: T
Unit group: 7_1
Min
-1000000.0000 [Nm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 10th value pair of the friction characteristic.
Dependency:
Refer to: p3829, p3845
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: p0505
Max
1000000.0000 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
1000000.0000 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
1000000.0000 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
1000000.0000 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
1000000.0000 [Nm]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7010
Factory setting
0.0000 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7010
Factory setting
0.0000 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7010
Factory setting
0.0000 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7010
Factory setting
0.0000 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7010
Factory setting
0.0000 [Nm]
459