2 Parameters
2.2 List of parameters
r1537[0...1]
Current limit minimum torque-generating current / Isq_min
Access level: 4
Can be changed: -
Unit group: 6_2
Min
- [Arms]
Description:
Displays the minimum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
Index:
[0] = Limited
[1] = Unlimited
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1538
CO: Upper effective torque limit / M_max upper eff
Access level: 2
Can be changed: -
Unit group: 7_1
Min
- [Nm]
Description:
Display and connector output for the actual effective upper torque limit.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
The effective upper torque limit is reduced with respect to the selected upper torque limit p1520, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
This may be the case for rotating measurements (see p1960).
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
r1539
CO: Lower effective torque limit / M_max lower eff
Access level: 2
Can be changed: -
Unit group: 7_1
Min
- [Nm]
Description:
Display and connector output for the actual effective lower torque limit.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
The effective lower torque limit is reduced with respect to the selected lower torque limit p1521, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
This may be the case for rotating measurements (see p1960).
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
p1545[0...n]
BI: Activates travel to a fixed stop / TfS activation
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source to activate/deactivate the "travel to fixed stop" function
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
268
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6640, 6710
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6020, 6640
Factory setting
- [Nm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6020, 6640
Factory setting
- [Nm]
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 2520, 3617, 8012
Factory setting
0
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890