Download Print this page

Siemens SINAMICS G120 List Manual page 393

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

r2527.0...2
CO/BO: LR actual value sensing status word encoder 1 / ActValSensZSW enc1
CU250S_V (Position
Access level: 1
control)
Can be changed: -
CU250S_V_CAN
Unit group: -
(Position control)
Min
CU250S_V_DP
-
(Position control)
CU250S_V_PN
(Position control)
Description:
Display and BICO output for the status word of the position actual value sensing from encoder 1.
Bit field:
Bit
00
01
02
r2528.0...2
CO/BO: LR actual value sensing status word encoder 2 / ActValSensZSW enc2
CU250S_V (Position
Access level: 1
control)
Can be changed: -
CU250S_V_CAN
Unit group: -
(Position control)
Min
CU250S_V_DP
-
(Position control)
CU250S_V_PN
(Position control)
Description:
Display and BICO output for the status word of the position actual value sensing from encoder 2.
Bit field:
Bit
00
01
02
p2530
CI: LR position setpoint / s_set
CU250S_V (Position
Access level: 1
control)
Can be changed: T
CU250S_V_CAN
Unit group: -
(Position control)
Min
CU250S_V_DP
-
(Position control)
CU250S_V_PN
(Position control)
Description:
Sets the signal source for the position setpoint of the position controller.
Dependency:
Refer to: r2665
p2531
CI: LR velocity setpoint / v_set
CU250S_V (Position
Access level: 1
control)
Can be changed: T
CU250S_V_CAN
Unit group: -
(Position control)
Min
CU250S_V_DP
-
(Position control)
CU250S_V_PN
(Position control)
Description:
Sets the signal source for the velocity setpoint of the position controller.
Dependency:
Refer to: r2666
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
Position actual value valid
Referencing active
Measured value valid
Signal name
Position actual value valid
Referencing active
Measured value valid
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
Data type: U32 / Integer32
Dyn. index: -
Func. diagram: 4015, 4020
Factory setting
2665[0]
Data type: U32 / Integer32
Dyn. index: -
Func. diagram: 4015
Factory setting
2666[0]
FP
-
-
-
FP
-
-
-
393

Hide quick links:

Advertisement