Dependency:
The simulation of a digital input is selected using p0795.
Refer to: p0795
Notice:
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
p0797[0...1]
CU analog inputs simulation mode / CU AI sim_mode
Access level: 3
Can be changed: U, T
Unit group: -
Min
0
Description:
Sets the simulation mode for the analog inputs.
Value:
0:
1:
Index:
[0] = AI0 (T. 3/4)
[1] = AI1 (T. 10/11)
Dependency:
The setpoint for the input voltage is specified via p0798.
Refer to: p0798
Note:
This parameter is not saved when data is backed up (p0971).
AI: Analog Input
p0798[0...1]
CU analog inputs simulation mode setpoint / CU AI sim setp
Access level: 3
Can be changed: U, T
Unit group: -
Min
-50.000
Description:
Sets the setpoint for the input value in the simulation mode of the analog inputs.
Index:
[0] = AI0 (T. 3/4)
[1] = AI1 (T. 10/11)
Dependency:
The simulation of an analog input is selected using p0797.
If AI x is parameterized as a voltage input (p0756), the setpoint is a voltage in V.
If AI x is parameterized as a current input (p0756), the setpoint is a current in mA.
Refer to: p0756, p0797
Note:
This parameter is not saved when data is backed up (p0971).
AI: Analog Input
p0802
Data transfer: memory card as source/target / mem_card src/targ
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the number for data transfer of a parameter backup from/to memory card.
Transfer from memory card to device memory (p0804 = 1):
- sets the source of parameter backup (e.g. p0802 = 48 --> PS048xxx.ACX is the source).
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
DI 19 (T. 44)
DI/DO 24 (T. 51)
DI/DO 25 (T. 52)
DI/DO 26 (T. 53)
DI/DO 27 (T. 54)
Terminal evaluation for analog input x
Simulation for analog input x
High
High
High
High
High
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
2000.000
Calculated: -
Scaling: -
Unit selection: -
Max
100
2 Parameters
2.2 List of parameters
Low
Low
Low
Low
Low
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.000
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
-
-
-
-
-