r8939
PN DAP ID / PN DAP ID
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the PROFINET Device Access Point ID (DAP ID) for the onboard PROFINET interface.
The combination of device ID (r8909) and DAP ID uniquely identifies a PROFINET access point.
Note:
List of the SINAMICS DAP IDs:
20007 hex: CBE20 V4.5
20008 hex: CBE20 V4.6
20107 hex: CU310-2 PN V4.5
20108 hex: CU310-2 PN V4.6
20307 hex: CU320-2 PN V4.5
20308 hex: CU320-2 PN V4.6
20407 hex: CU230P-2 PN /CU240x-2 PN V4.5
20408 hex: CU230P-2 PN /CU240x-2 PN /CU250S-2 PN /G110M PN V4.6
20507 hex: CU250D-2 PN V4.5
20508 hex: CU250D-2 PN V4.6
r8960[0...2]
PN subslot controller assignment / PN subslot assign
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the controller assignment of a PROFINET subslot on the actual drive object.
Index:
[0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Dependency:
Refer to: r8961, r8962
Note:
Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
r8961[0...3]
PN IP Address Remote Controller 1 / IP Addr Rem Ctrl1
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the IP address of the first PROFINET controller connected with the device via PN onboard.
r8962[0...3]
PN IP Address Remote Controller 2 / IP Addr Rem Ctrl2
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the IP address of the second PROFINET controller connected with the device via PN onboard.
536
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
8
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
255
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-