r8930[0...239]
PN Name of Station actual / PN Name Stat act
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the actual station name for the onboard PROFINET interface on the Control Unit.
r8931[0...3]
PN IP address actual / PN IP addr act
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the actual IP address for the onboard PROFINET interface on the Control Unit.
r8932[0...3]
PN Default Gateway actual / PN Def Gateway act
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the actual default gateway for the onboard PROFINET interface on the Control Unit.
r8933[0...3]
PN Subnet Mask actual / PN Subnet Mask act
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the actual subnet mask for the onboard PROFINET interface on the Control Unit.
r8934
PN DHCP Mode actual / PN DHCP Mode act
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the actual DHCP mode for the onboard PROFINET interface on the Control Unit.
Value:
0:
2:
3:
Notice:
When the DHCP mode is active (parameter value not equal to 0), PROFINET communication via this interface is no
longer possible! However, the interface can be used for commissioning tool such as STARTER or SCOUT.
r8935[0...5]
PN MAC address / PN MAC addr
CU250S_V_PN
Access level: 3
Can be changed: -
Unit group: -
Min
0000 hex
Description:
Displays the MAC address for the onboard PROFINET interface on the Control Unit.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
DHCP off
DHCP on, identification using MAC address
DHCP on, identification via name of station
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
3
Calculated: -
Scaling: -
Unit selection: -
Max
00FF hex
2 Parameters
2.2 List of parameters
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
535

Hide quick links:

Advertisement

loading