n_ctrl config
p1400 [D]
1
2
Vector control / U/f control
Speed control configuration
Speed control configuration
Bit No.
Meaning
1 = Automatic Kp/Tn adaptation active
00
1 = Sensorless vector control, freeze I component
01
...
Reserved
05
1 = Kp/Tn adaptation active
06
1 = Free Tn adaptation active
...
Reserved
1 = Torque pre-control always active
14
0 = Torque pre-control for n_ctrl enabled
1 = Sensorless vector control, speed pre-control active
15
1 = I component for limiting enabled
16
...
Reserved
18
1 = Moment of inertia estimator active
19
Reserved
1 = Acceleration model
20
Reserved
21
22
1 = Obtain moment of inertia estimator value for pulse inhibit
23
1 = acceleration model (with speed encoder)
24
1 = moment of inertia estimator quick estimation active
25
1 = Acceleration torque instantaneous in the I/f mode
3
4
Factory setting
[6040.2]
1
[6824.4]
[6040.6]
0
[6824.6]
[6040.2]
1
[6824.4]
0
[6050.6]
[6060.4]
0
[6826.4]
[6030.6]
1
[6822.4]
0
0
0
0
0
0
0
5
6
Function diagram
fp_6490_97_63.vsd
G120 CU250S-2
05.09.2017
V4.7.9
7
8
- 6490 -