p2098[0...1]
Inverter connector-binector converter binector output / Con/bin outp inv
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p2098[0], the signals of connector input p2099[0] are influenced.
Using p2098[1], the signals of connector input p2099[1] are influenced.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Dependency:
Refer to: r2094, r2095, p2099
p2099[0...1]
CI: Connector-binector converter signal source / Con/bin S_src
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on
(interconnection).
Dependency:
Refer to: r2094, r2095
Note:
From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p2099[0...1] together with r2094.0...15 and r2095.0...15 forms two connector-binector converters:
Connector input p2099[0] to binector output in r2094.0...15
Connector input p2099[1] to binector output in r2095.0...15
p2100[0...19]
Change fault response fault number / Chng resp F_no
Access level: 3
Can be changed: U, T
Unit group: -
Min
0
Description:
Selects the faults for which the fault response should be changed
Dependency:
The fault is selected and the required response is set under the same index.
Refer to: p2101
Note:
Re-parameterization is also possible if a fault is present. The change only becomes effective after the fault has been
resolved.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
65535
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2468, 9360
Factory setting
0000 0000 0000 0000 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Data type: U32 / Integer16
Dyn. index: -
Func. diagram: 2468, 9360
Factory setting
0
Data type: Unsigned16
Dyn. index: -
Func. diagram: 8050, 8075
Factory setting
0