For distance-coded zero marks, the following applies:
The phase sequence of the C/D track (if available) must be the same as the phase sequence of the encoder (A/B
track).
The phase sequence of the Hall signal (if available) must be the same as the phase sequence of the motor. Further,
the position of the Hall sensor must be mechanically adjusted to the motor EMF.
The fine synchronization is only started after two zero marks have been passed.
p0405[0...n]
Square-wave encoder track A/B / Sq-wave enc A/B
Access level: 3
Can be changed: C(4)
Unit group: -
Min
-
Description:
Settings for the track A/B in a square-wave encoder.
For square-wave encoders, p0404.3 must also be 1.
Bit field:
Bit
00
01
02
03
04
05
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For bit 02:
When the function is activated, track monitoring can be deactivated by setting p0437.26.
For bit 05:
When the function is activated, a frequency setpoint and a direction for traveling can be entered via an encoder
interface.
p0407[0...n]
Linear encoder grid division / Enc grid div
Access level: 3
Can be changed: C(4)
Unit group: -
Min
0 [nm]
Description:
Sets the grid division for a linear encoder.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
The lowest permissible value is 250 nm.
p0408[0...n]
Rotary encoder pulse number / Rot enc pulse No.
Access level: 3
Can be changed: C(4)
Unit group: -
Min
0
Description:
Sets the number of pulses for a rotary encoder.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
The number of pole pairs for a resolver is entered here.
The smallest permissible value is 1 pulse.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
Signal
Level
Track monitoring
Zero pulse
Switching threshold
Pulse/direction
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Bipolar
TTL
A/B <> -A/B
Same as A/B track
High
Active
Calculated: -
Scaling: -
Unit selection: -
Max
250000000 [nm]
Calculated: -
Scaling: -
Unit selection: -
Max
16777215
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: 4704
Factory setting
0000 1111 bin
0 signal
Unipolar
HTL
None
24 V unipolar
Low
Inactive
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: 4010, 4704
Factory setting
16000 [nm]
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: 4010, 4704
Factory setting
2048