Note:
For index 0:
Firmware version on the memory card/device memory.
For index 1:
Actual firmware version of the DRIVE-CLiQ component.
For index 2 ... 6:
Actual EEPROM version of the DRIVE-CLiQ component.
r7827
Firmware update progress display / FW update progress
Access level: 3
Can be changed: -
Unit group: -
Min
- [%]
Description:
Displays the progress when updating the firmware of the DRIVE-CLiQ components.
p7830
Telegram diagnostics selection / Telegr diag sel
Access level: 4
Can be changed: T
Unit group: -
Min
0
Description:
Selects a telegram whose contents should be shown in r7831 ... r7836.
Value:
0:
1:
2:
3:
Dependency:
Refer to: r7831, r7832, r7833, r7834, r7835, r7836
r7831[0...23]
Telegram diagnostics signals / Telegr diag sig
Access level: 4
Can be changed: -
Unit group: -
Min
0
Description:
Displays the signals contained in the selected telegram (p7830).
Value:
0:
1:
102:
110:
111:
112:
113:
114:
115:
10500: ENC_ID_TIME_PRETRIGGER
10501: ENC_ID_TIME_SEND_TELEG_1
10502: ENC_ID_TIME_CYCLE_FINISHED
10503: ENC_ID_TIME_DELTA_FUNMAN
10504: ENC_ID_SUBTRACE_CALCTIMES
10505: ENC_ID_SYNO_PERIOD
10516: ENC_ID_ADC_TRACK_A
10517: ENC_ID_ADC_TRACK_B
10518: ENC_ID_ADC_TRACK_C
10519: ENC_ID_ADC_TRACK_D
10520: ENC_ID_ADC_TRACK_A_SAFETY
10521: ENC_ID_ADC_TRACK_B_SAFETY
10523: ENC_ID_ADC_TEMP_1
10524: ENC_ID_SUBTRACE_TRACK_A
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Reserved
First cyclic receive telegram sensor 1
First cyclic receive telegram sensor 2
First cyclic receive telegram sensor 3
UNUSED
UNKNOWN
SAPAR_ID_DSA_ALARM
SAPAR_ALARMBITS_FLOAT_0
SAPAR_ALARMBITS_FLOAT_1
SAPAR_ALARMBITS_FLOAT_2
SAPAR_ALARMBITS_FLOAT_3
SAPAR_ALARMBITS_FLOAT_4
SAPAR_ALARMBITS_FLOAT_5
Calculated: -
Scaling: -
Unit selection: -
Max
- [%]
Calculated: -
Scaling: -
Unit selection: -
Max
3
Calculated: -
Scaling: -
Unit selection: -
Max
15157
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [%]
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
-
495