p6397
Motor module phase shift second system / MM ph_sh 2nd sys
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the phase shift of the second system with respect to the first system for the motor module for a 12-pulse gating
unit.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
Notice:
The parameter is only evaluated if p7003 = 2.
Note:
For p6397 = 0 the following applies: The second systems leads for a positive direction of rotation.
For p6397 = 1 the following applies: The second systems lags for a positive direction of rotation.
r7758[0...19]
KHP Control Unit serial number / KHP CU ser_no
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the actual serial number of the Control Unit.
The individual characters of the serial number are displayed in the ASCII code in the indices.
For the commissioning software, the ASCII characters are displayed uncoded.
Dependency:
Refer to: p7765, p7766, p7767, p7768
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Note:
KHP: Know-How Protection
p7759[0...19]
KHP Control Unit reference serial number / KHP CU ref ser_no
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the reference serial number for the Control Unit.
Using this parameter, if a Control Unit and/or a memory card is replaced at the end customer, the OEM can again
adapt the project to the modified hardware.
Dependency:
Refer to: p7765, p7766, p7767, p7768
Note:
KHP: Know-How Protection
- the OEM may only change this parameter for the use case "Sending encrypted SINAMICS data".
- SINAMICS only evaluates this parameter when powering up from the encrypted "Load into file system..." output or
when powering up from the encrypted PS files. The evaluation is only made when know-how protection and memory
card copy protection have been activated.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Shift by +30 °
Shift by -30 °
Shift by 0 °
Shift by +90 °
Shift by -90 °
Shift by +120 °
Shift by -120 °
Shift by +150 °
Shift by -150 °
Calculated: -
Scaling: -
Unit selection: -
Max
8
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-