2 Parameters
2.2 List of parameters
For this device specialization, the components of the target topology may only differ from those of the actual topology
by the serial numbers and order numbers.
Note:
p9905 is automatically set to 0 at the end of the operation.
In order to permanently accept the data, it is necessary to save in a non-volatile fashion (p0977).
p9910
Target topology accept additional components / Add comp accept
Access level: 1
Can be changed: -
Unit group: -
Min
0
Description:
Accept additional inserted DRIVE-CLiQ components into the target topology.
The corresponding drive objects are added to the project.
Value:
0:
1:
2:
3:
4:
5:
6:
p9915
DRIVE-CLiQ data transfer error shutdown threshold master / DQ fault master
Access level: 4
Can be changed: C(1)
Unit group: -
Min
0000 hex
Description:
Only for internal Siemens service purposes.
p9916
DRIVE-CLiQ data transfer error shutdown threshold slave / DQ fault slave
Access level: 4
Can be changed: C(1)
Unit group: -
Min
0000 hex
Description:
Only for internal Siemens service purposes.
p9920[0...99]
Licensing enter license key / Enter license key
Access level: 2
Can be changed: U, T
Unit group: -
Min
-
Description:
Enters the license key for this drive unit.
Example of the license key:
EACZ-QBCA = 69 65 67 90 45 81 66 67 65 dec (ASCII characters)
Index 0 = license key character 1 (e.g. 69 dec)
Index 1 = license key character 2 (e.g. 65 dec)
...
Index 8 = license key character 9 (e.g. 65 dec)
Index 9 = license key character 10 (e.g. 0 dec)
...
Dependency:
Refer to: r7843, p9921
Refer to: A13000, A13001, F13010
592
No selection
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Calculated: -
Scaling: -
Unit selection: -
Max
6
Calculated: -
Scaling: -
Unit selection: -
Max
0007 07FF hex
Calculated: -
Scaling: -
Unit selection: -
Max
0007 07FF hex
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0007 02FF hex
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0007 02FF hex
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890