Siemens SINAMICS G120 List Manual page 836

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

Bit No.
Control word
<1> [2855.4]
0
1 = STO de-select
<2> [2858.3]
<1> [2855.4]
1 = SS1 de-select
1
<2> [2858.3]
Reserved
2
Reserved
3
<1> [2855.4]
4
1 = SLS de-select
<2> [2858.3]
5
Reserved
6
Reserved
<1> [2855.4]
7
1/0 = Acknowledgment
<2> [2858.3]
Reserved
8
1 = Select SLS bit 0
<2>
[2858.3]
9
[2858.3]
1 = Select SLS bit 1
<2>
10
11
Reserved
<1> [2855.4]
12
1 = De-select SDI positive
<2> [2858.3]
<1> [2855.4]
13
1 = De-select SDI negative
<2> [2858.3]
<1>
This applies to activation via F-DI (p9601.2/p9801.2 = 1, p9601.3/p9801.3 = 0).
This applies to activation via PROFIsafe (p9601.2/9801.2 = 1, p9601.3/9801.3 =
<2>
1).
<3>
Reserved for activation via F-DI.
1
2
Safety Integrated Extended Functions
Control and status word
SI Mtn integ STW
r9720
r9720
<1> [2855.6]
r9720.0
<2> [2858.6]
<1> [2855.6]
r9720.1
<2> [2858.6]
<1> [2855.6]
r9720.4
<2> [2858.6]
<1> [2855.6]
r9720.7
<2> [2858.6]
<1> [2855.6]
<3>
r9720.9
<2> [2858.6]
<1> [2855.6]
<3>
r9720.10
<2> [2858.6]
<1> [2855.6]
r9720.12
<2> [2858.6]
<1> [2855.5]
r9720.13
<2> [2858.6]
<1> [2855.6]
<2> [2858.6]
3
4
Bit No.
Status word
0
1 = STO or safe pulse cancellation active
1 = SS1 active
1
Reserved
2
Reserved
3
4
1 = SLS active
5
Reserved
6
Reserved
7
1 = Not an internal event
Reserved
8
1 = Active SLS stage, bit 0
9
1 = Active SLS stage, bit 1
10
11
Reserved
12
1 = SDI positive active
13
1 = SDI negative active
14
Reserved
1 = SSM (Speed below limit)
15
5
6
Function diagram
fp_2840_97_55.vsd
G120 CU250S-2
05.09.2017
V4.7.9
SI Mtn int stat P1
r9722
r9722
r9722.0
r9722.1
r9722.4
r9722.7
r9722.9
r9722.10
r9722.12
r9722.13
r9722.15
7
8
- 2840 -