p1020 [C]
p1021 [C]
p1022 [C]
p1023 [C]
p1110 [C]
p1111 [C]
p1113 [C]
(2090.11)
p1035 [C]
(2090.13)
p1036 [C]
(2090.14)
p1122 [C]
1
2
Internal control/status words
Control word, setpoint channel (r1198)
Bit No.
n_set_fixed Bit 0
(0)
0
1 = Fixed setpoint, bit 0
n_set_fixed Bit 1
(0)
1
1 = Fixed setpoint, bit 1
n_set_fixed Bit 2
(0)
1 = Fixed setpoint, bit 2
2
n_set_fixed Bit 3
(0)
1 = Fixed setpoint, bit 3
3
4
Reserved
Inhib neg dir
(0)
5
1 = Inhibit negative direction
Inhib pos dir
(0)
6
1 = Inhibit positive direction
Reserved
7
Reserved
8
9
Reserved
10
Reserved
Setp inv
11
1 = Setpoint inversion
Reserved
12
Mop raise
1 = Motorized potentiometer, raise
13
Mop lower
1 = Motorized potentiometer, lower
14
Bypass RFG
(0)
15
1 = Bypass ramp-function generator
3
4
Control word setpoint channel (r1198)
5
6
fp_2505_97_51.vsd
05.09.2017
STW setpoint chan
r1198
r1198
To fixed speed setpoints [3010.2], [3011.2]
r1198.0
To control word 2 [2513.2]
To fixed speed setpoints [3010.2], [3011.2]
r1198.1
To control word 2 [2513.2]
To fixed speed setpoints [3010.2], [3011.2]
r1198.2
To control word 2 [2513.2]
To fixed speed setpoints [3010.2], [3011.2]
r1198.3
To control word 2 [2513.2]
To direction of rotation limiting and
r1198.5
direction of rotation reversal [3040.3]
To direction of rotation limiting and
r1198.6
direction of rotation reversal [3040.5]
To direction of rotation limiting and
r1198.11
direction of rotation reversal [3040.2]
To control word 1 [2512.4]
r1198.13
To the motorized potentiometer [3020.1]
To control word 1 [2512.4]
r1198.14
To the motorized potentiometer [3020.1]
To the ramp-function generator [3060.1],
r1198.15
[3070.1]
7
Function diagram
G120 CU250S-2
V4.7.9
8
- 2505 -