Download Print this page

Siemens SINAMICS G120 List Manual page 553

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

r9485
BICO interconnections signal source search count / BICO S_src srchQty
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
Dependency:
Refer to: p9484, r9486
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
r9486
BICO interconnections signal source search first index / BICO S_src srchIdx
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the first index of the signal source being searched for.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the
number (r9485) and the first index (r9486).
Dependency:
Refer to: p9484, r9485
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
p9495
BICO behavior for deactivated drive objects / Behav for deact DO
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the behavior for BICO interconnections to drive objects that are either not capable of operation or have been
deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Value:
0:
1:
2:
Dependency:
Refer to: p9496, p9497, p9498, p9499
Refer to: A01318, A01507
Note:
For p9495 = 0, the following applies:
- the number of interconnections is zero (p9497 = 0).
For p9495 not equal to 0, the following applies:
- the BI/CI parameters involved are listed in p9498[0...29] (signal sink).
- the associated BO/CO parameters are listed in p9499[0...29] (signal source).
p9496
BICO behavior when activating drive objects / Behav when act DO
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the behavior when activating BICO interconnections to drive objects that are either not capable of operation or
have been deactivated.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Inactive
Save interconnections
Save interconnections and establish the factory setting
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
2
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
553

Hide quick links:

Advertisement

loading