p10139
SI Motion Safe State signal selection (processor 2) / SI Safe State P2
Access level: 3
Can be changed: C(95)
Unit group: -
Min
-
Description:
Selects the individual signals that should be logically combined to create "Safe State".
Bit field:
Bit
00
01
04
05
06
p10142[0...5]
SI Motion F-DO signal sources (processor 2) / SI F-DO S_src P2
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0
Description:
Sets the signal sources for F-DO 0
The 6 signal sources in p10142[0...5] are AND'ed and the result is output at F-DO 0.
Value:
0:
1:
2:
5:
6:
7:
9:
12:
13:
Index:
[0] = AND logic operation input 1
[1] = AND logic operation input 2
[2] = AND logic operation input 3
[3] = AND logic operation input 4
[4] = AND logic operation input 5
[5] = AND logic operation input 6
Note:
F-DO: Fail-safe Digital Output
p10146
SI Motion test sensor feedback signal (processor 2) / SI test sens FS P2
Access level: 3
Can be changed: C(95)
Unit group: -
Min
-
Description:
Sets the test of the feedback line for forced checking procedure.
Bit field:
Bit
00
Note:
F-DO: Fail-safe Digital Output
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
Power_removed
SS1_active
SLS_active
SDI_pos_active
SDI_neg_active
No function
STO active
SS1 active
SLS active
SSM feedback signal active
Safe state
Internal event
SDI positive active
SDI negative active
Signal name
Test F-DO 0
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Selected
Selected
Selected
Selected
Selected
Calculated: -
Scaling: -
Unit selection: -
Max
13
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Test active
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2856
Factory setting
0000 0001 bin
0 signal
Not selected
Not selected
Not selected
Not selected
Not selected
Data type: Integer16
Dyn. index: -
Func. diagram: 2857
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2848
Factory setting
0000 bin
0 signal
No test
FP
-
-
-
-
-