Download Print this page

Siemens SINAMICS G120 List Manual page 649

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

r20185
BO: PST 1 output Q / PST 1 output Q
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: -
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
-
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Display parameter for output pulse Q of instance PST 1 of the pulse extension element.
p20186
PST 1 run-time group / PST 1 RTG
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
5
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for the run-time group in which the instance PST 1 of the pulse extension element is to be called.
Value:
5:
6:
9999: Do not calculate
p20187
PST 1 run sequence / PST 1 RunSeq
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
0
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for the run sequence of instance PST 1 within the run-time group set in p20186.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20188[0...1]
BI: RSR 0 inputs / RSR 0 inputs
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
-
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Sets the signal source for set input S and reset input R of instance RSR 0 of the RS flipflop.
Index:
[0] = Set S
[1] = Reset R
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
7999
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7234
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7234
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7234
Factory setting
500
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7240
Factory setting
0
649

Hide quick links:

Advertisement

loading