Download Print this page

Siemens SINAMICS G120 List Manual page 568

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

2 Parameters
2.2 List of parameters
p9659
SI forced checking procedure timer / SI FCP Timer
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0.00 [h]
Description:
Sets the time interval for carrying out the forced checking procedure and testing the Safety switch-off signal paths.
Within the parameterized time, STO must have been de-selected at least once. The monitoring time is reset each
time that STO is de-selected.
Dependency:
Refer to: A01699
Note:
STO: Safe Torque Off
r9660
SI forced checking procedure remaining time / SI FCP remain
Access level: 3
Can be changed: -
Unit group: -
Min
- [h]
Description:
Displays the time remaining before dynamization and testing of the safety switch-off signal paths (forced checking
procedure).
Dependency:
Refer to: A01699
p9661
SI forced checking procedure STO via PM terminals time / FCP_dyn STO PM-T t
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0.00 [h]
Description:
Sets the time interval for monitoring the forced checking procedure and testing the Safety switch-off signal paths for
STO via terminals on the Power Module.
Within the parameterized time, STO must have been de-selected at least once.
Dependency:
Refer to: r9662
Refer to: A01678
Note:
STO: Safe Torque Off
r9662
SI forced checking procedure STO via PM terminals remaining time /
FCP_dyn STO PM-T t
Access level: 3
Can be changed: -
Unit group: -
Min
- [h]
Description:
Displays the remaining time for monitoring the forced checking procedure and testing the Safety switch-off signal
paths for STO via terminals on the Power Module.
After the monitoring time set in p9661 has expired, an appropriate alarm is output.
Dependency:
Refer to: p9661
Refer to: A01678
Note:
PM: Power Module
STO: Safe Torque Off
568
Calculated: -
Scaling: -
Unit selection: -
Max
9000.00 [h]
Calculated: -
Scaling: -
Unit selection: -
Max
- [h]
Calculated: -
Scaling: -
Unit selection: -
Max
9000.00 [h]
Calculated: -
Scaling: -
Unit selection: -
Max
- [h]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2810
Factory setting
8.00 [h]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [h]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
8.00 [h]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [h]
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890

Hide quick links:

Advertisement

loading