p2619[0...n]
EPOS traversing block acceleration override / Trav_block a_over
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: U, T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
1.0 [%]
CU250S_V_PN
(EPOS)
Description:
Sets the acceleration override for the traversing block.
The override refers to the maximum acceleration (p2572).
Dependency:
The number of indices depends on p2615.
Refer to: p2572, p2615, p2616, p2617, p2618, p2620, p2621, p2622, p2623, p2624
p2620[0...n]
EPOS traversing deceleration override / Trav_block -a_over
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: U, T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
1.0 [%]
CU250S_V_PN
(EPOS)
Description:
Sets the deceleration override for the traversing block.
The override refers to the maximum deceleration (p2573).
Dependency:
The number of indices depends on p2615.
Refer to: p2573, p2615, p2616, p2617, p2618, p2619, p2621, p2622, p2623, p2624
Notice:
If, when calculating the traversing profile, it is identified that the target position of the next block with the programmed
deceleration override will not be reached without direction reversal (flying block change), then the old (actual)
deceleration override remains effective.
p2621[0...n]
EPOS traversing block task / Trav_block task
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: U, T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
1
CU250S_V_PN
(EPOS)
Description:
Sets the required task for the traversing block.
Value:
1:
2:
3:
4:
5:
6:
7:
8:
9:
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2622, p2623, p2624
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
POSITIONING
FIXED STOP
ENDLESS_POS
ENDLESS_NEG
WAITING
GOTO
SET_O
RESET_O
JERK
Calculated: -
Scaling: -
Unit selection: -
Max
100.0 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
100.0 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
9
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: p2615
Func. diagram: 3616
Factory setting
100.0 [%]
Data type: FloatingPoint32
Dyn. index: p2615
Func. diagram: 3616
Factory setting
100.0 [%]
Data type: Integer16
Dyn. index: p2615
Func. diagram: 3616
Factory setting
1
419