Download Print this page

Siemens SINAMICS G120 List Manual page 839

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

Statically active
F-DI 0
[2850.8]
F-DI 1
[2850.8]
F-DI 2
[2850.8]
Statically inactive
SI Mtn STO F-DI P1
0 ... 255
p10022 (0)
SI STO F-DI P2
0 ... 255
p10122 (0)
SI Mtn SS1 F-DI P1
0 ... 255
p10023 (0)
SI SS1 F-DI P2
0 ... 255
p10123 (0)
SI Mtn SLS F-DI P1
0 ... 255
p10026 (0)
SI SLS F-DI P2
0 ... 255
p10126 (0)
SI SDI pos F-DI P1
0 ... 255
p10030 (0)
SI SDI pos F-DI P2
0 ... 255
p10130 (0)
SI SDI neg F-DI P1
0 ... 255
p10031 (0)
SI SDI neg F-DI P2
0 ... 255
p10131 (0)
SI Mtn ackn int P1
0 ... 255
p10006 (0)
SI ackn int evt P2
0 ... 255
p10106 (0)
1
2
Safety Integrated Extended Functions
Extended Functions via F-DI (p9601.2 = 1 and p9601.3 = 0)
F-DI assignment
SI Mtn integ STW
1 = De-select STO
r9720
r9720
.0
[2819.1], [2840.1]
1 = De-select SS1
r9720.1
[2819.1], [2840.1]
1 = De-select SLS
r9720.4
[2820.1], [2840.1]
1 = Acknowledgment
r9720.7
[2840.1]
Select SLS bit 0
r9720.9
[2840.1]
Select SLS bit 1
r9720.10
[2840.1]
1 = De-select SDI positive
r9720.12
[2824.1], [2840.1]
1 = De-select SDI negative
r9720.13
[2824.1], [2840.1]
3
4
SI Motion
SI Mtn int stat P1
1 = STO active
r9722
r9722
.0
[2819.8], [2840.5]
1 = SS1 active
r9722.1
[2819.8], [2840.5]
1 = SLS active
r9722.4
[2820.8], [2840.5]
Internal event
r9722.7
[2840.5]
1 = Active SLS stage, bit 0 set
r9722.9
Safe motion
[2820.8], [2840.5]
monitoring
1 = Active SLS stage, bit 1 set
r9722.10
[2820.8], [2840.5]
1 = SDI pos active
r9722.12
[2824.8], [2840.5]
1 = SDI neg active
r9722.13
[2824.8], [2840.5]
1 = SSM (n below limit)
r9722.15
[2823.8], [2840.5]
5
6
fp_2855_97_55.vsd
05.09.2017
V4.7.9
[2856.1]
[2857.1]
7
8
Function diagram
- 2855 -