2 Parameters
2.2 List of parameters
2:
3:
4:
6:
7:
8:
9:
10:
11:
255:
r0964[0...6]
Device identification / Device ident
Access level: 2
Can be changed: -
Unit group: -
Min
-
Description:
Displays the device identification.
Index:
[0] = Company (Siemens = 42)
[1] = Device type
[2] = Firmware version
[3] = Firmware date (year)
[4] = Firmware date (day/month)
[5] = Number of drive objects
[6] = Firmware patch/hot fix
Note:
Example:
r0964[0] = 42 --> SIEMENS
r0964[1] = device type, see below
r0964[2] = 403 --> first part of the firmware version V04.03 (for second part, refer to index 6)
r0964[3] = 2010 --> year 2010
r0964[4] = 1705 --> 17th of May
r0964[5] = 2 --> 2 drive objects
r0964[6] = 200 --> second part, firmware version (complete version: V04.03.02.00)
Device type:
r0964[1] = 6363 --> SINAMICS G120 CU250S-2 VECTOR
r0964[1] = 6360 --> SINAMICS G120 CU250S-2_DP VECTOR
r0964[1] = 6361 --> SINAMICS G120 CU250S-2_PN VECTOR
r0964[1] = 6362 --> SINAMICS G120 CU250S-2_CAN VECTOR
r0965
PROFIdrive profile number / PD profile number
CU250S_V_DP
Access level: 3
CU250S_V_PN
Can be changed: -
Unit group: -
Min
-
Description:
Displays the PROFIdrive profile number and profile version.
Constant value = 0329 hex.
Byte 1: Profile number = 03 hex = PROFIdrive profile
Byte 2: Profile version = 29 hex = Version 4.1
Note:
When the parameter is read via PROFIdrive, the Octet String 2 data type applies.
174
93.75 kbit/s
187.5 kbit/s
500 kbit/s
1.5 Mbit/s
3 Mbit/s
6 Mbit/s
12 Mbit/s
31.25 kbit/s
45.45 kbit/s
Unknown
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890