2 Parameters
2.2 List of parameters
Dependency:
The functions in p9938 can only be set for p9937.0 = 0.
Refer to: r9936, p9937, p9939, p9942
Notice:
If value = 0:
- detailed diagnostics is inactive.
- the error counter is active (r9936).
If value > 0:
- the error counter is inactive (r9936).
- the detailed diagnostics as configured is active (r9943).
p9939
DRIVE-CLiQ detailed diagnostics time interval / DQ detail t_interv
Access level: 4
Can be changed: U, T
Unit group: -
Min
1 [s]
Description:
Sets the time interval for recording the error counter in r9943.
Dependency:
Refer to: r9936, p9938, p9942, r9943
p9942
DRIVE-CLiQ detailed diagnostics select individual connection / DQ detail conn
Access level: 4
Can be changed: U, T
Unit group: -
Min
0
Description:
Sets the component, whose feeder cable is monitored for data transfer errors.
The feeder cable is the DRIVE-CLiQ cable that is connected to a component in the direction of the Control Unit.
Errors that have occurred in the selected time interval (p9939) can be read-out from r9943.
Dependency:
Refer to: r9936, p9938, p9939, r9943
r9943
DRIVE-CLiQ detailed diagn. individual connection error counter / DQ det err counter
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Displays the connection errors of the individual connection that have occurred within the time interval (p9939).
The detailed diagnostics for the individual connection is activated via p9938 > 0 and is selected via p9942.
Dependency:
Refer to: r9936, p9938, p9939, p9942
r9975[0...7]
System utilization measured / Sys util meas
Access level: 4
Can be changed: -
Unit group: -
Min
- [%]
Description:
Displays the measured system utilization.
The higher the value displayed, the higher the system utilization.
Index:
[0] = Computing time utilization (min)
[1] = Computing time utilization (averaged)
[2] = Computing time utilization (max)
[3] = Largest total utilization (min)
[4] = Largest total utilization (averaged)
596
Calculated: -
Scaling: -
Unit selection: -
Max
3600 [s]
Calculated: -
Scaling: -
Unit selection: -
Max
199
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
- [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
1 [s]
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [%]
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890