Siemens SINAMICS G120 List Manual page 471

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

Dependency:
Refer to: r4653, r4654, p4655
Note:
The absolute value is only valid after passing the zero mark.
If value = 1:
The value in XIST1_ERW is reset when passing every zero mark.
If value = 2:
The value in XIST1_ERW is reset with a 0/1 edge via binector input p4655.
If value = 3:
The value in XIST1_ERW is reset after a 0/1 edge via binector input p4655 when passing the next zero mark.
r4653[0...2]
CO: XIST1_ERW actual value / XIST1_ERW actval
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display and connector output for the actual value XIST1_ERW.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p4652, r4654, p4655
r4654.0...8
CO/BO: XIST1_ERW status / XIST1_ERW stat
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display and BICO output to reset XIST1_ERW.
Bit field:
Bit
00
08
Dependency:
Refer to: p4652, r4653, p4655
Note:
The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
p4655[0...2]
BI: XIST1_ERW reset signal source / XIST1_ERW resS_src
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source to reset XIST1_ERW (CO: r4653).
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p4652, r4653, r4654
Note:
The reset of XIST1_ERW depends on the selected mode (p4652).
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
Encoder 1 XIST1_ERW reset
Encoder 2 XIST1_ERW reset
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
High
High
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 4750
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 4750
Factory setting
-
0 signal
Low
Low
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 4750
Factory setting
0
FP
-
-
471