p0782[0...1]
BI: CU analog outputs invert signal source / CU AO inv S_src
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Sets the signal source to invert the analog output signals.
Index:
[0] = AO0 (T 12/13)
[1] = AO1 (T 26/27)
Note:
AO: Analog Output
T: Terminal
r0785.0...1
BO: CU analog outputs status word / CU AO ZSW
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the status of analog outputs.
Bit field:
Bit
00
01
Note:
AO: Analog Output
p0791[0...1]
CO: Fieldbus analog outputs / Fieldbus AO
CU250S_V
Access level: 3
Can be changed: U, T
Unit group: -
Min
-200.000 [%]
Description:
Setting and connector output to control the analog outputs via fieldbus.
Index:
[0] = AO0 (T 12/13)
[1] = AO1 (T 26/27)
Dependency:
Refer to: p0771
Note:
AO: Analog Output
The following interconnections must be established to control the analog outputs via fieldbus:
- AO 0: p0771[0] with p0791[0]
- AO 1: p0771[1] with p0791[1]
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
AO 0 negative
AO 1 negative
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
200.000 [%]
2 Parameters
2.2 List of parameters
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 9572
Factory setting
0
Data type: Unsigned16
Dyn. index: -
Func. diagram: 9572
Factory setting
-
0 signal
No
No
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.000 [%]
FP
-
-