Download Print this page

Siemens SINAMICS G120 List Manual page 197

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

r1084
CO: Speed limit positive effective / n_limit pos eff
Access level: 3
Can be changed: -
Unit group: 3_1
Min
- [rpm]
Description:
Display and connector output for the active positive speed limit.
Dependency:
Refer to: p1082, p1083, p1085
Note:
Vector control: r1084 <= 60 x 240 Hz / r0313
p1085[0...n]
CI: Speed limit in positive direction of rotation / n_limit pos
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the speed limit of the positive direction.
p1086[0...n]
CO: Speed limit in negative direction of rotation / n_limit neg
Access level: 3
Can be changed: U, T
Unit group: 3_1
Min
-210000.000 [rpm]
Description:
Sets the speed limit for the negative direction.
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
r1087
CO: Speed limit negative effective / n_limit neg eff
Access level: 3
Can be changed: -
Unit group: 3_1
Min
- [rpm]
Description:
Display and connector output for the active negative speed limit.
Dependency:
Refer to: p1082, p1086, p1088
Note:
Vector control: r1087 >= -60 x 240 Hz / r0313
p1088[0...n]
CI: Speed limit in negative direction of rotation / n_limit neg
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the speed/velocity limit of the negative direction.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
0.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3050, 7958
Factory setting
- [rpm]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 3050
Factory setting
1083[0]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3050
Factory setting
-210000.000 [rpm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3050, 7958
Factory setting
- [rpm]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 3050
Factory setting
1086[0]
197

Hide quick links:

Advertisement