2 Parameters
2.2 List of parameters
p2193[0...n]
Load monitoring configuration / Load monit config
CU250S_V (Ext msg)
Access level: 3
CU250S_V_CAN (Ext
Can be changed: U, T
msg)
Unit group: -
CU250S_V_DP (Ext
Min
msg)
0
CU250S_V_PN (Ext
msg)
Description:
Sets the load monitoring configuration.
Value:
0:
1:
2:
3:
Dependency:
Refer to: p2182, p2183, p2184, p2185, p2186, p2187, p2188, p2189, p2190, p2192, r2198, p3230, p3231, p3232
Refer to: A07920, A07921, A07922, F07923, F07924, F07925, F07936
p2194[0...n]
Torque threshold value 2 / M_thresh val 2
Access level: 3
Can be changed: U, T
Unit group: -
Min
0.00 [%]
Description:
Sets the torque threshold value for the message "Torque utilization < torque threshold value 2" (BO: r2199.11).
The message "torque setpoint < p2174" (BO: r2198.10) and "torque utilization < p2194" (BO: r2199.11) are only
evaluated after the run-up and the delay time has expired.
Dependency:
Refer to: r0033, p2195, r2199
p2195[0...n]
Torque utilization switch-off delay / M_util t_off
Access level: 3
Can be changed: U, T
Unit group: -
Min
0.0 [ms]
Description:
Sets the switch-off delay time for the negated signal "run-up completed".
The message "torque setpoint < p2174" (BO: r2198.10) and "torque utilization < p2194" (BO: r2199.11) are only
evaluated after the run-up and the delay time has expired.
Dependency:
Refer to: p2174, p2194
p2196[0...n]
Torque utilization scaling / M_util scal
Access level: 1
Can be changed: C(1, 3), U, T
Unit group: -
Min
0.00 [%]
Description:
Sets the scaling factor for torque utilization (r0033).
360
Monitoring switched out
Monitoring torque and load drop
Monitoring speed and load drop
Monitoring load drop
Calculated: -
Scaling: -
Unit selection: -
Max
3
Calculated: p0340 = 1,3,5
Scaling: -
Unit selection: -
Max
100.00 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
1000.0 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
1000.00 [%]
Data type: Integer16
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
1
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8012
Factory setting
90.00 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8012
Factory setting
800.0 [ms]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
100.00 [%]
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890